NRP18S-xx High Power Triple Diode Power Sensor
Fast and accurate power measurement of CW and modulated signals; maximum dynamic range: -60 dBm to +45 dBm; controlled and monitored via USB; 10 000 triggered measurements per second; over 50,000 readings per second; built-in trigger I/O port
NRP2 Power Meter
Supports all NRPxxS/SN, NRPxxT/TN and NRPxxA/ AN USB and LAN power sensors; supports all NRP-Zxx power sensors; supports all sensor-related measurement functions; expands to up to four measurement channels; optional integration 50 MHz / 1 mW reference source; hardware interface for remote control and triggering
3986 Series Noise Figure Analyzer
3986 series noise figure analyzer products include 3986A (10MHz ~ 4GHz), 3986D (10MHz ~ 18GHz), 3986E (10MHz ~ 26.5GHz), 3986F (10MHz ~ 40GHz) and 3986H (10MHz ~ 50GHz), with wide frequency coverage, The frequency band is flexible, the receiving sensitivity is high, the user interface is friendly, the large-screen dual-channel high-definition display, the peripheral interface is rich, and the dual noise source is driven. Capable of measuring noise figure and gain of amplifier, upconverter and downconverter, supporting automatic measurement of noise figure of multi-stage inverter receiving link
Infrared Camera
Get infrared tools based on more than 65 years of industrial experience. Each camera or infrared window is manufactured in strict accordance with Fluke's “Resiliency, Reliability and Accuracy” standards. Designed for everyday use in any environment for comprehensive and accurate inspection. For thermal imaging cameras, choose hand-held and fixed installation tools
279FC Economical Multimeter Thermal Imager
The 279FC Economy Multimeter Thermal Imager helps you quickly identify, repair, verify and report on a wide range of electrical issues, giving you the confidence to solve any problem. At the same time with thermal imaging, multimeter and clamp function, cost-effective; a total of 15 measurement functions, including: AC voltage (with low-pass filter), DC voltage, resistance, continuity, capacitance, diode detection, minimum / Maximum/average, AC current (via iFlex flexible current probe), frequency
U2002A USB Power Sensor
Frequency range: 50 MHz to 24 GHz; option H26 extends frequency from 10 MHz to 26.5 GHz; wide dynamic range: -60 to +20 dBm; with internal zeroing, no external calibration required; up to 250 readings/second High measurement speed; support for internal and external trigger measurements; display of power measurements on PC or other Keysight instruments; internal trigger and trace display