U2002A USB Power Sensor
Frequency range: 50 MHz to 24 GHz; option H26 extends frequency from 10 MHz to 26.5 GHz; wide dynamic range: -60 to +20 dBm; with internal zeroing, no external calibration required; up to 250 readings/second High measurement speed; support for internal and external trigger measurements; display of power measurements on PC or other Keysight instruments; internal trigger and trace display
U2001A USB Power Sensor
Frequency range: 10 MHz to 6 GHz; option H3 extends frequency from 3 MHz to 6 GHz; wide dynamic range: -60 to +25 dBm (depending on sensor option); with internal zeroing, no external calibration required High measurement speeds up to 250 readings/second; support for internal and external trigger measurements; display of power measurements on PC or other Keysight instruments; internal trigger and trace display
U2000A USB Power Sensor
Frequency range: 10 MHz to 18 GHz; wide dynamic range: -60 to +20 dBm; with internal zeroing, no external calibration required; high measurement speed of up to 250 readings/second; support for internal and external triggering measurements; Power measurement results on PC or other Keysight instruments; internal trigger and trace display
E4416A EPM-P Series Single Channel Power Meter
The E4416A power meter is compatible with all 8480 and E series power meters; 20 M samples per second for reliable continuous and single measurements of wideband signals; time gating and free running power measurements; free analyzer software Suitable for complete pulse and statistical analysis in the literature library; 8 pre-defined wireless configurations (GSM, EDGE, NADC, iDEN, Bluetooth&trade, IS-95 CDMA, W-CDMA and cdma 2000)
N1912A P Series Dual Channel Power Meter
30 MHz video bandwidth; single-shot real-time capture at a sampling rate of 100 Msa/s; key measurement parameters: - peak, average, peak-to-average ratio, rise time, fall time, and pulse width; 22 predefined formats: WiMAX , DME, HSDPA, etc.; a screen view showing a variety of pulse measurement and analysis results: automatic scaling, auto strobing, rise/fall time, duty cycle, etc.; internal zeroing and calibration when connected to the device under test; Enable BenchVue software
N1911A P Series Single Channel Power Meter
30 MHz video bandwidth; single-shot real-time capture at a sampling rate of 100 Msa/s; key measurement parameters: “peak, average, peak-to-average ratio, rise time, fall time, and pulse width; 22 predefined systems: WiMAX , DME, HSDPA, etc.; a screen view showing a variety of pulse measurement and analysis results: automatic scaling, auto strobing, rise/fall time, duty cycle, etc.; internal zeroing and calibration when connected to the device under test; Enable BenchVue software